Skip to content

Gravity: I2C SCD41 Infrared CO2 Sensor (400 - 5000 ppm)

89 units will be available shortly.

Express post shipping available (product is on backorder)

CO2 is a key factor for indoor air quality as high levels compromise human cognitive performance and well-being.

This Gravity: SCD41 CO2 sensor is based on the SCD41 miniature CO2 sensor from Sensirion. SCD41 builds on the photoacoustic NDIR sensing principle and Sensirion’s patented PAsens® and CMOSens® technology to offer high accuracy at an unmatched price and the smallest form factor. On-chip signal compensation is realized with the built-in temperature and humidity sensor, while temperature and humidity data outputs are also available.

SCD41 sensor detects the amount of energy that is absorbed by CO2 molecules. When pulsing the infrared emitter, CO2 molecules absorb infrared light periodically. This causes additional molecular vibration resulting in a pressure wave inside the measurement chamber. The higher the CO2 concentration, the more light is absorbed, and thus the greater the amplitude of this acoustic wave becomes. A microphone inside the gas chamber measures this, from which the CO2 concentration can then be calculated.

Click to learn more about PAsens® technology.

Click to learn more about NDIR sensors.




Gravity CO2 Sensor Selection Guide




Product Name Gravity: Analog Electrochemistry CO2 Sensor Gravity: Analog IR CO2 Sensor Gravity: UART IR CO2 Sensor Gravity: I2C SCD41 Infrared CO2 Sensor (400 - 5000 ppm)
SKU SEN0159 SEN0219 SEN0220 SEN0536
Operation Voltage 3.7~5V 4.5~5.5V 4.5~5.5V 3.3V-5V
Output
Gravity: Analog
(Analog2.7~4.1V)
+
3P Header Digital Output(Alarm):0~VCC Level
Gravity: Analog
(Analog Output 0.4~2V)
Gravity: UART
(0~3.3V Level)
Gravity: I2C
Measurement Principle
Electrochemistry
(Solid electrolyte battery principle)
NDIR(non-dispersive infrared) NDIR(non-dispersive infrared) photoacoustic NDIR
Measurement Range 0~10000 ppm 0~5000 ppm 0~50000 ppm 400~5000ppm
Accuracy ±100ppm@400ppm ±(100ppm + 6% readings) ±(100ppm + 6% readings) ±(40 ppm + 5% MV)

Response 

Time

<20s <90s <30s 60S

Average 

Power

<1W <430mW@5V <430mW@5V <30mW@5V
Operation Temperature -20°C~50°C 0°C~50°C 0°C~50°C -10°C~60°C
Operation Humidity 0~95% RH (No condensation) 0~95% RH (No condensation) 0~95% RH (No condensation) 0~95% RH (No condensation)
Lifespan >1 year >5 years >5 years >10 years
Dimension
(PCB)
32*42 mm 37*69 mm 21*27.1 mm 32*27*8mm
Features
1. Large Range
2. Adjustable Alarm Threshold
3. Fast Response
4. Analog Output
1. High Accuracy
2. Long Lifespan
3. Auto Temperature Compensation
4. Water Vapor Interference Resistance
5. Ananglog Output
1. High Accuracy
2. Large Range
3. Long Lifespan
4. Auto Temperature Compensation
5. Water Vapor Interference Resistance
6.3.3V UART Output
1.CO2, temperature, and humidity, three in one
2. Small size of 32*27*8mm
3. Low power, average current<4mA


Features
  • CO2, temperature, and humidity, three in one
  • Small size of 32*27*8mm
  • Low power, average current<4mA

  • Applications
  • Indoor CO2 concentration monitoring
  • Ambient monitoring in greenhouse
  • Smart ventilation systems

  • Specification
  • Power Supply: 3.3V to 5V
  • Average Operating Current: <4mA
  • I2C Address: 0x62
  • Product Size: 32*27*8mm/1.26×1.06×0.31"

  • CO2

  • Accuracy: ±(40 ppm + 5% MV)
  • Measuring Range: 400 - 5000 ppm
  • Response Time: 60s

  • Humidity

  • Typical Relative Humidity Accuracy: 6%RH
  • Relative Humidity Measuring Range: 0 to 95%RH
  • Response Time: 120s

  • Temperature

  • Typical Temperature Accuracy: 0.8°C
  • Temperature Measuring Range: -10 to 60°C
  • Response Time: 120s

  • Documents
  • Product wiki
  • Schematics
  • Dimensions
  • Design-in guide

  • Shipping List

  • Gravity: SCD41 Infrared CO2 Sensor x1
  • Gravity-4P I2C/UART Sensor Cable x1
  • The Gravity: I2C SCD41 Infrared CO2 Sensor (400 - 5000 ppm) appears in the following collections: