SparkFun
STCC4/SHT40 Qwiic CO2 Sensor
·
Measure indoor CO2 concentration, temperature and relative humidity over I2C with this dual-sensor breakout. The Sensirion STCC4 uses thermal conductivity to...
Get notified when back in stock
Measure indoor CO2 concentration, temperature and relative humidity over I2C with this dual-sensor breakout. The Sensirion STCC4 uses thermal conductivity to measure CO2 directly, while the SHT40 provides temperature and humidity data for compensated CO2 readings.
Two Qwiic connectors make it easy to connect the board and add other I2C devices. A 0.1-inch-spaced plated through-hole header also breaks out power and I2C for soldered connections. The STCC4 address can be changed with the ADDR jumper on the back of the board.
The STCC4 uses automatic self-calibration to maintain accuracy over time. It needs an initial 12 hours of operation and exposure to fresh air containing at least 400 ppm CO2 once a week. After a power-down of more than three hours, run it for an hour to restore measurement accuracy. SparkFun provides an STCC4 Arduino library, hookup guide, schematic and KiCad files.
Features:
- Direct CO2 measurement: The STCC4 measures CO2 using thermal conductivity, rather than estimating concentration.
- Environmental compensation: The SHT40 supplies temperature and humidity data for CO2 readings.
- Automatic self-calibration: Helps maintain CO2 measurement accuracy over time.
- STCC4 I2C interface: Two addresses selectable using the ADDR jumper.
- SHT40 I2C interface: Separate address for temperature and humidity readings.
- Qwiic connections: Two connectors support daisy-chained I2C wiring.
- Soldered connection option: A 0.1-inch-spaced plated through-hole header breaks out power and I2C.
- Power indicator: Red power LED.
Specifications:
- STCC4 CO2 measurement range: 400 to 5000 ppm
- STCC4 CO2 output range: 380 to 32,000 ppm
- STCC4 CO2 measurement accuracy: ± 100 ppm + 10% of reading, with SHT40 temperature and humidity compensation
- STCC4 digital resolution: 1 ppm
- STCC4 response time: 20s
- STCC4 supply voltage: 2.7 to 5.5V (3.3V Typ)
- STCC4 peak supply current: 3.7mA
- STCC4 average supply current, continuous mode: 950µA
- STCC4 average supply current, single shot mode (10s intervals): 100µA
- STCC4 average supply current, idle mode: 55µA
- STCC4 average supply current, sleep mode: 1µA
- STCC4 communication: I2C
- STCC4 selectable I2C addresses: Two
- STCC4 default I2C address: 0x64
- STCC4 alternate I2C address: 0x65
- SHT40 operating temperature range: -40 to +125°C
- SHT40 temperature accuracy: ±0.2°C
- SHT40 operating humidity range: 0 to 100% RH
- SHT40 humidity accuracy: ±1.8% RH
- SHT40 humidity response time: 4s
- SHT40 temperature response time: 2s
- SHT40 supply voltage: 1.08 to 3.6V (3.3V Typ)
- SHT40 average supply current, heater off, measurement: 320µA (Typ), 500µA (Max)
- SHT40 average supply current, heater off, power up: 50µA
- SHT40 average supply current, heater off, idle: 0.08µA (Typ), 3.4µA (Max)
- SHT40 maximum current draw, heater on: 100mA
- SHT40 communication: I2C
- SHT40 I2C address: 0x44
- Qwiic connectors: 2
- Plated through-hole header: 1, 0.1-inch spaced
- Power LED: Red
Find this product in
STCC4/SHT40 Qwiic CO2 Sensor Schematic
Schematic · 122.2 KB · Click any page to view full size
STCC4 Datasheet
Datasheet · 743.8 KB · Click any page to view full size
SHT4x Datasheet
Datasheet · 881.2 KB · Click any page to view full size
Resources & Downloads
Guides, code examples, and more
Jargon buster
Plain-language definitions for the technical terms in the product description.
- Automatic Self-Calibration
- Automatic Self-Calibration is a built-in routine that adjusts the sensor over time to reduce drift in its readings. It matters for long-running indoor monitors because it can help keep measurements stable without frequent manual calibration.
- breakout
- A breakout board carries a small or fine-pitched component and brings its connections out to standard, breadboard- and header-friendly pins. Describing a part as a breakout means it can be wired into a project without soldering directly to the component's tiny contacts.
- I2C
- I2C is a two-wire communication bus used by many sensors and small modules. It matters because several I2C devices can share the same two wires, but each device needs a compatible address and your controller must support I2C.
- I2C address
- An I2C address is the number a device uses so a microcontroller can tell it apart from other devices on the same I2C bus. It matters because two devices with the same fixed address may conflict if used together.
- LED
- A light-emitting diode (LED) is a small electronic component that emits light when current flows through it in the correct direction. Because it only conducts one way, its polarity matters, and a through-hole LED must be soldered the correct way around to light up.
- ppm
- ppm means parts per million, a common way to express very small gas concentrations in air. For CO₂ sensors, the ppm range tells you what levels the sensor can measure, such as normal indoor air through to poorly ventilated spaces.
- Qwiic
- Qwiic is a plug-in connector system for I2C devices that uses small 4-pin cables, so you can connect compatible sensors without soldering. It matters because your controller or adapter also needs Qwiic, or you will need a cable or breakout to wire it up.
- SHT40
- The SHT40 is a Sensirion digital temperature and humidity sensor. It reports ambient temperature and relative humidity, and those readings are sometimes used to compensate other measurements such as CO₂.
- STCC4
- STCC4 is a Sensirion gas-sensing chip that measures carbon dioxide (CO₂) concentration. Knowing which sensing chip a module uses helps you find compatible libraries, datasheets and performance specifications before using it in a project.
- through-hole
- A mounting style where the component leads pass through holes in a circuit board and are soldered on the other side. Through-hole parts are often easier to handle and solder by hand, which is useful for classroom and hobby projects.