DFRobot
Industrial 4-Channel Relay Module
The module adopts the standard Modbus RTU protocol, the communication interface supports RS485 or RS232 and supports communication baud rates of 2400, 4800, ...
The module adopts the standard Modbus RTU protocol, the communication interface supports RS485 or RS232 and supports communication baud rates of 2400, 4800, 9600, 19200, 38400 (default 9600). Each relay output is independent and can be connected to different load devices, such as 220V electric lights, 24V solenoid valves, etc. Both AC and DC devices can be controlled. Each relay output contact is isolated and can set 0-255 device addresses. It can be switched on and off very quickly. This industrial 4-channel relay module allows you to control your electrical equipment only through one computer serial port. It supports DC7-30V wide voltage power supply, optocoupler isolation, four-way switching input, and four-way relay output. The management and controlling of electrical equipment can be completed by a computer, which makes this module able to be widely used in scenarios like factories, hotels, etc., as well as lighting control in stages, homes, cinemas, etc., and can also be used for motor control, production line control, etc.
The module adopts the standard Modbus RTU protocol, the communication interface supports RS485 or RS232 and supports communication baud rates of 2400, 4800, 9600, 19200, 38400 (default 9600). Each relay output is independent and can be connected to different load devices, such as 220V electric lights, 24V solenoid valves, etc. Both AC and DC devices can be controlled. Each relay output contact is isolated and can set 0-255 device addresses. It can be switched on and off very quickly. The module adopts the standard Modbus RTU protocol, the communication interface supports RS485 or RS232 and supports communication baud rates of 2400, 4800, 9600, 19200, 38400 (default 9600). Each relay output is independent and can be connected to different load devices, such as 220V electric lights, 24V solenoid valves, etc. Both AC and DC devices can be controlled. Each relay output contact is isolated and can set 0-255 device addresses. It can be switched on and off very quickly.
Specification
Documents
Shipping List
Jargon buster
Plain-language definitions for the technical terms used above.
- baud
- Baud is the signalling rate of a serial connection, often used as the speed setting for UART communication. Matching the baud rate matters because both connected devices must use the same setting for readable data.
- LED
- A light-emitting diode is a small electronic component that lights up when current flows through it in the correct direction. In this kit, LEDs create the flashing effect, so polarity and correct soldering matter for the project to work.
- Modbus
- Modbus is an industrial communication protocol used by many meters, sensors, PLCs, and automation devices. Modbus support matters because it can make the controller easier to integrate with existing industrial equipment.
- Modbus RTU
- Modbus RTU is a version of Modbus commonly used over RS485 serial wiring. It matters if you need to connect the controller to industrial sensors, meters, or drives that use serial Modbus rather than Ethernet.
- RS485
- RS485 is a robust wired serial communication standard often used in factories, farms, and buildings where cables may be long or electrically noisy. It matters because it lets this controller connect to industrial sensors, meters, and control equipment over longer distances than typical hobby serial wiring.
Find this product in
Brands
Robotics & Motion
Supplier page — dfrobot.com
Supplier Description · 634.8 KB · Click any page to view full size
Related Tutorials
Free guides on learn.littlebird.com.au